<LOGO>
FM Transmitter Measurement Report
Created: 2024-10-22 00-52-09
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 70 dBuV YLEX
Pilot RDS Phase Difference
7.2 kHz 2.2 kHz 62 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 64 kHz 19080 1,0692
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,2 dBr 3,43 dBr 5,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"YLEX " 6202 10 (Pop M) 0 1 1 1 0:52, 22.10.2024
RT
"YleX Iltapäivä: Päivän parhaat "
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6205, 6201, 6203, 6207
FM Scope Max at: 64 kHz MIN: 9 kHz % above 76 kHz: 1,0692 Acquired: 2024/10/22 0.51.05 Total samples: 19080 Equivalent time: 0:15:54 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 5,2 dBr MIN: 1,2 dBr AVE: 3,43 dBr % above 12,2 dBr: 0,0 Last value: 5,1 dBr (2024/10/22 0.51.05) 00.38 00.40 00.42 00.44 00.46 00.48 00.50 0 50 100 Dev. MAX [kHz] 0 2 4 6 Pm [dBr]